Northern UTA220/UTA220k Manuel D’Utilisation

Page de 187
10-2
UTA220/UTA220k
BONDING
PLACING A BONDING CALL
You can place a call from port 1 or port 2 using any normal 
means. The answering party must be set to run BONDING or 
the call will disconnect shortly after connection. If you specify 
a rate multiplier of 2 and the answering party indicates it will 
support 2 or more channels for BONDING, the answering side 
will pass the directory number for the second call in the 
negotiation. The second call is made automatically. You can 
tell this call is being made by the flashing LED on the second 
B-channel. If delay equalization between the channels is 
obtained, data mode is entered. The front panel indicates the 
BONDING connection, the B-channel line speed (56 or 64 
kbps), and the DTE speed (56, 64, 112, or 128 kbps). The 
B-channel LEDs remain on when data mode has been entered.
Note: When a rate multiple of 2 is negotiated, both B-channels 
are used. The remaining ports are prevented from making 
circuit switched calls for the duration of the BONDING call. 
If the rate multiple is set to 1 on either the originator or 
answerer, the second call will not be made and data mode will 
be entered immediately after negotiation. The second call will 
not be made and data mode will be entered immediately after 
negotiation. The screen will indicate the speed the call 
connected at.
The Directory Numbers configured in the D-channel setup tell 
the origination side what the second Directory Number is. If 
you are using a point-to-point line with only one Directory 
Number, on answering a BONDING call that is requesting two 
channels, this directory number will be sent to the origination 
side, which is the same number as the first one dialed. This is 
because a point-to-point line can receive two calls using the 
same Directory Number. AT&T 5E5/5E6 can also be 
configured to receive two calls using the same Directory 
Number. To use this capability, change port 1’s SEC CALL 
PORT (located under BONDING OPTIONS in 
CONFIGURATION / PORT) to 1 and set port 2’s SEC CALL 
PORT to 2.
DISCONNECTING A BONDING CALL
Disconnecting by any normal means disconnects all 
BONDING channels. If either channel is disconnected by the 
switch, the entire call is disconnected by the UTA220. The 
disconnection can be validated by the LCD screen indicating 
DISCONNECTED and the B1 and B2 LEDs being off.