Kärcher 600 CD Manuel D’Utilisation

Page de 93
17
WTC 600 LP / MP
DESCRIPTION
Service Handbook 08.2004
2.4
Technical Data WTC 600 LP/MP
Parameter
WTC 600 LP
WTC 600 MP
Ambient temperature
 +1°C - +50°C
Storage temperature (delivery)
 to -10°C
Humidity
<100% r.F.
Supply voltage
3*400V 50 Hz
1)
1*230V 50 Hz
1)
Pre-filter controls: prim / sec.
230 V/12 V 50 Hz
Metering pumps
230 V 50-60Hz
Wiring
3 Ph, N, PE
Electrical protection
16 A
Connected electrical load
2.2 kW
2.2 kW
Effective electrical power consumption
1.5 kW
2.2 kW
Mechanical protection / protection against water
Switch cabinet
IP44
Pump and valves
IP44
Metering pump
IP44
Power outlets (plug inserted)
< IP44
Minimum temperature of untreated water
+5°C
Maximum temperature of untreated wate
+35°C
Reference temperature
+15°C
pH-value, untreated water
6-9.5
pH-value during cleaning
3-11
System input pressure and flow
2-6 bar at min. 2 m³/h
Capacity range
15000 l/day (±10%)
Maximum drinking water capacity
650 l/h
Dimensions: H x W x D
WTC 600 LP/MP
1800 x 660 x 720 mm
WTC 600 LP/MP - A
1800 x 1120 x 720 mm
WTC 600 LP/MP - AM
1800 x 1120 x 720 mm
Weight in delivery condition (without filter container)
WTC 600 LP/MP
135 kg
WTC 600 LP/MP - A
155 kg
WTC 600 LP/MP - AM
175 kg
 Table 3
Technical Data
1)
 depending on the system version