Microsoft ES4625 Manuel D’Utilisation
System Management Commands
4-61
4
show system
This command displays system information.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Command Usage
• For a description of the items shown by this command, refer to “Displaying
• The POST results should all display “PASS.” If any POST test indicates
“FAIL,” contact your distributor for assistance.
Example
Console#show system
System description: 44GE+4Combo Layer2/3/4 Stackable Switch
System OID string: 1.3.6.1.4.1.259.6.10.64
System information
System description: 44GE+4Combo Layer2/3/4 Stackable Switch
System OID string: 1.3.6.1.4.1.259.6.10.64
System information
System Up time: 0 days, 1 hours, 23 minutes, and 44.61 seconds
System Name
System Name
: [NONE]
System Location
: [NONE]
System Contact
: [NONE]
MAC Address (Unit1):
00-20-1A-DF-9C-A0
MAC Address (Unit2):
00-20-1A-DF-9E-C0
Web Server:
Enabled
Web Server Port:
80
Web Secure Server:
Enabled
Web Secure Server Port:
443
Telnet Server:
Enable
Telnet Server Port:
23
Jumbo Frame:
Disabled
POST Result:
DUMMY Test 1 ................. PASS
UART Loopback Test ........... PASS
DRAM Test .................... PASS
Timer Test ................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Switch Int Loopback Test ..... PASS
Crossbar Int Loopback Test ... PASS
Fan Speed Test ............... PASS
UART Loopback Test ........... PASS
DRAM Test .................... PASS
Timer Test ................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Switch Int Loopback Test ..... PASS
Crossbar Int Loopback Test ... PASS
Fan Speed Test ............... PASS
Done All Pass.
Console#
Console#