Basic Configuration
3-13
3
CLI – Specify the hostname, location and contact information.
Displaying Switch Hardware/Software Versions 
Use the Switch Information page to display hardware/firmware version numbers for 
the main board and management software, as well as the power status of the 
system.
Field Attributes
Main Board
• Serial Number – The serial number of the switch.
• Number of Ports – Number of built-in ports.
• Hardware Version – Hardware version of the main board.
• Internal Power Status – Displays the status of the internal power supply.
Management Software
• EPLD Version – Version number of EEPROM Programmable Logic Device.
• Loader Version – Version number of loader code.
• Boot-ROM Version – Version of Power-On Self-Test (POST) and boot code.
Console(config)#hostname R&D 5
Console(config)#snmp-server location WC 9
Console(config)#snmp-server contact Ted
Console(config)#exit
Console#show system
System description: 44GE+4Combo Layer2/3/4 Stackable Switch
System OID string: 1.3.6.1.4.1.259.6.10.64
System information
System Up time:
0 days, 1 hours, 28 minutes, and 0.51 seconds
System Name:
R&D 5
System Location:
WC 9
System Contact:
Ted
MAC Address (Unit1):
00-20-1A-DF-9C-A0
MAC Address (Unit2):
00-20-1A-DF-9E-C0
Web Server:
Enabled
Web Server Port:
80
Web Secure Server:
Enabled
Web Secure Server Port:
443
Telnet Server:
Enable
Telnet Server Port:
23
Jumbo Frame:
Disabled
POST Result:
DUMMY Test 1 ................. PASS
UART Loopback Test ........... PASS
DRAM Test .................... PASS
Timer Test ................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Switch Int Loopback Test ..... PASS
Crossbar Int Loopback Test ... PASS
Fan Speed Test ............... PASS
Done All Pass.