Microtest TSB-67 - 568A Annex E Manuel D’Utilisation

Page de 61
Editing Test Limits
To display the 
EDIT LIMITS 
screen, press the 
Extended Functions
 key, then 
select Setup
Autotest
, then highlight the Autotest to edit, then press 
Edit (F2),
 then select Limits. This screen
lets you specify the PASS/FAIL limits used in tests.
Press the
 Ñ 
or
 Ò 
arrow key to highlight the test for which you want to edit the limits.
Press
 Select (F1)
 to display the limits screen for the highlighted test. Or, press the number on the
keypad that corresponds to the test for which you want to change the limits.
After editing the selected limits, press 
Save (F1)
 to save these changes and to return to the
 EDIT
LIMITS
 screen.
If you have created a new Autotest by editing the Autotest name or by editing a factory-
programmed Autotest, and if you want the new test to be the default Autotest, press 
ESCAPE
until you return to the 
AUTOTEST SETUP
 screen, then press 
Default (F1).
Note: See the individual test sections for information on customizing specific test limits.
Running Autotest
To display the 
AUTOTEST:
 screen, press the 
AUTOTEST
 key. This screen is displayed while
Autotest is running. The Autotest name is displayed at the top of the screen and the cable type is
shown in the top center of the screen. Each pair being tested is displayed in the lower left corner of
the screen. The name of each test being run is displayed in the lower right corner of the screen. A
status bar at the bottom of the screen indicates the progress of the Autotest.
Press the 
ESCAPE
 key at any time to cancel the Autotest.
Note: The Injector must be attached to the far end of the cable during Autotest. If it is not, the
Scanner screen will display the following:
Searching for Injector . . . (Injector Not Found)
Autotest Results Screen
To display the 
AUTOTEST RESULTS 
screen, press the 
AUTOTEST
 key, or press 
the Extended
Functions
 key and select 
Memory
. This screen is displayed when Autotest completes or when
saved Autotest results are selected for viewing.
The Autotest name is at the top right of the display and the PASS/FAIL indicator is in the center.
The number of failed tests, if any, is displayed next to the PASS/FAIL indicator. An Autotest will
PASS if all the selected tests meet the specified criteria. An Autotest will FAIL if one or more
selected tests fail. When the Margin Display is set to 
TIA Margin Display 
an Autotest will
marginally PASS (*PASS) if one or more NEXT, Attenuation or Length measurements marginally
passes. A marginal PASS is defined as a PASS result that is closer to the PASS/FAIL threshold than
the accuracy of the Scanner.
Press 
View (F1)
 to display Autotest results, then use the 
Ñ 
or 
Ò 
arrow keys to scroll through
the tests. The tests you view depend on the tests you have selected to run in 
AUTOTEST SETUP
.
See Selecting Tests to Run During Autotest for more information.
Press 
Save (F2)
 to save test results and exit. See Saving Autotest Results for more information.
Note: The 
Save (F2)
 key is unavailable when viewing the 
AUTOTEST RESULTS
 screen via the
Extended Functions/Memory