Automatic Transition 
At this juncture, you would replace the failed drive in slot 3 with a new one of the same or greater capacity.  
 
When the Astra ES controller detects the new drive in slot 3, it will: 
• 
Automatically transition the data on drive 6 to drive 3 
• 
Return drive 6 to spare status 
When the Automatic Transition is finished, physical drives 1, 2, 3, and 4 belong to the disk array and physical 
drive 6 is a revertible spare drive. The original configuration is restored. 
Manual Transition 
If you wanted to use the drive in slot 5 as a member of the disk array, rather than the drive in slot 3, you would 
run the Transition function manually.  
 
When the Manual Transition is finished, physical drives 1, 2, 4, and 5 belong to the disk array and physical drive 
6 is a revertible spare drive.  
At this point, you would replace the drive in slot 3. The new drive in slot 3 will be unconfigured until you assign it 
to a disk array or as a spare.