APPLICATION NOTE 3918
User's Guide for the MAX6877 Power-Supply Tracker/Sequencer
Abstract: This application note is a step-by-step User's Guide for designing with the MAX6877 voltage tracker and 
sequencer. The note explains how to make suitable component calculations.
 
 
Figure 1. The basic circuit for the MAX6877. 
 Overview
     
Tracks or sequences up to three voltages 
     
Closed-loop tracking control with programmable slew rate 
     
Program thresholds with resistors 
     
Program slew rate and timing delays with capacitors 
     
Fault output and power-good output 
Description
The MAX6877 voltage tracker/sequencer can track or sequence up to three voltages. Use the TRACK/SEQ pin to select 
tracking or sequencing. The device will either track or sequence the three voltages, but it cannot track and sequence 
simultaneously. Power-up begins when EN/active-low UV is asserted and all three input voltages are above their 
thresholds. In the example circuit in Figure 1, EN/active-low UV is connected to the 12V bus, so the circuit will turn 
on when the bus exceeds its threshold and turn off when it falls under its threshold.