Lucent Technologies Window SLV 9124 Manuel D’Utilisation

Page de 271
Security and Logins
 4-11
9124-A2-LB20-00
March 2000
more information about SNMP NMS Security configuration options.
Creating a Login
A login is required if security is enabled.*
  U
p to six login ID/password
combinations can be created using ASCII text, and each login must have a
specified access level. Logins must be unique and they are case-sensitive.
"
Procedure
To create a login record:
1. Select Administer Logins.
Main Menu
Control
Administer Logins
2. Select New, and set the following configuration options, as appropriate. 
In the field . . .
Enter the . . .
Login ID
ID of 1 to 10 characters.
Password
Password from 1 to 10 characters.
Re-enter password
Password again to verify that you entered the
correct password into the device.
Access Level
Access level: 1, 2, or 3.
H
Level-1 – User can add, change, and
display configuration options, save, and
perform device testing.
H
Level-2 – User can monitor and perform
diagnostics, display status and
configuration option information.
H
Level-3 – User can only monitor and
display status and configuration screens.
CAUTION: Make sure at least one login is set
up for Level-1 access or you may be
inadvertently locked out.
NOTE:
Troubleshooting, should you be locked out inadvertently.
3. Save your changes.
When Save is complete, the cursor is repositioned at the Login ID field, ready
for another entry.
*
Security is enabled by the configuration options Login Required for the communication port, modem port, and
Telnet Login Required or FTP Login Required for a Telnet or FTP Session.