Lucent Technologies Window SLV 9124 Manuel D’Utilisation
SNMP MIBs and Traps, and RMON Alarm Defaults
B-5
9124-A2-LB20-00
March 2000
NetScout Indexes to the Interface Table (ifTable)
For remote monitoring at sites where FrameSaver units are operating with
NetScout Probes, use the following ifName, ifDescr, and ifIndex.
NetScout Probes, use the following ifName, ifDescr, and ifIndex.
Table B-2.
NetScout Interface Objects Information
ifName
Description
ifDescr (ifEntry 2)
ifIndex
Frame Relay Logical Layer
Frame Relay 1
Network
Network
Frame relay logical
link on the network
interface
link on the network
interface
For the DTE side:
RMON (IN/OUT); Network T1
of FR DTE; T1 FR NAM;
Hardware Version: hhhh-hhh
RMON (IN/OUT); Network T1
of FR DTE; T1 FR NAM;
Hardware Version: hhhh-hhh
1
For the DCE side:
RMON (IN/OUT); Network T1
of FR SERVICE; T1 FR NAM;
Hardware Version: hhhh-hhh
RMON (IN/OUT); Network T1
of FR SERVICE; T1 FR NAM;
Hardware Version: hhhh-hhh
Frame Relay 3
Sync Data
Port 1
Sync Data
Port 1
Synchronous Data
Port-1
Port-1
For the user side:
RMON (IN/OUT); Synchronous
Data Port of FR DTE, Slot: 1,
Port: 1; T1 FR NAM; Hardware
Version: hhhh-hhh
RMON (IN/OUT); Synchronous
Data Port of FR DTE, Slot: 1,
Port: 1; T1 FR NAM; Hardware
Version: hhhh-hhh
3
For the network side:
RMON (IN/OUT); Synchronous
Data Port of FR SERVICE,
Slot: 1, Port: 1; T1 FR NAM;
Hardware Version: hhhh-hhh
RMON (IN/OUT); Synchronous
Data Port of FR SERVICE,
Slot: 1, Port: 1; T1 FR NAM;
Hardware Version: hhhh-hhh
RMON Logical Layer
RMON Frame
Relay Logical
Interfaces
Relay Logical
Interfaces
These values are
calculated.
calculated.
H
For the DTE:
OUT – RMON (IN);
[ifName of the interface]
[ifName of the interface]
17– 48
H
For the DTE:
(ifIndex –1) * 2 +17
H
For the DCE: DTE
calculated value +1
calculated value +1
OUT – RMON (OUT);
[ifName of the interface]
[ifName of the interface]
RMON Virtual
Interfaces
Interfaces
These values are
calculated based on
the probe’s internal
circuit index: circuit
index +65.
calculated based on
the probe’s internal
circuit index: circuit
index +65.
—
65 – 512
RMON Virtual
Logical
Interfaces
Logical
Interfaces
These values are
calculated.
calculated.
H
For the DTE:
(virtual interface
ifIndex
(virtual interface
ifIndex
65) * 2
IN – VIRTUAL PVC
[interface number ]
[DLCI number ] DTE
[interface number ]
[DLCI number ] DTE
513 –1023
ifIndex – 65) * 2
+513
+513
H
For the DCE:
DTE calculated
value +1
DTE calculated
value +1
OUT – VIRTUAL PVC
[interface number ]
[DLCI number ] DCE
[interface number ]
[DLCI number ] DCE