Configuring SNMP Traps and Trap Dial-Out
Select SNMP Traps from the Management and Communication menu to
configure SNMP traps and dial-out when a trap is generated (see Table 3-16).
format standards and special trap features, including RMON-specific traps, and
the default settings that will generate RMON-specific SNMP traps.
Table 3-16.
SNMP Traps and Trap Dial-Out Options (1 of 4)
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the FrameSaver unit sends trap messages to the currently
configured SNMP trap manager(s).
Enable – Sends trap messages.
Disable – Does not send trap messages.
Number of Trap Managers
Possible Settings: 1 – 6
Default Setting: 1
Specifies the number of SNMP management systems that will receive SNMP trap
messages from the FrameSaver unit. An NMS IP Address must be configured in the
NMS IP Address configuration option for each trap manager to receive trap
messages.
1 – 6 – Specifies the number of trap managers (inclusive).
NMS  IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: Clear (000.000.000.000)
Specifies the IP address that identifies the SNMP manager(s) to receive SNMP traps.
Display Conditions – This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
001.000.000.000 – 223.255.255.255 – Adds to or changes the IP address for the trap
manager.
Clear – Fills the NMS IP address with zeros.