Little Wonder 8221 Manuel D’Utilisation

Page de 20
7
Knobs previously installed.
E.  Changing the direction of the Discharge 
Chute (Figure #4)
1.   Loosen the Knobs (38524) by hand and, if needed, the 
Nuts (64229-03) with a 1/2” wrench.
2.   Rotate the Discharge Chute to the desired position.
3.   Retighten the Knobs by hand and the Nuts, if 
loosened, with the 1/2” wrench.
F.  Attaching the Hose Assembly to the Inlet 
Assembly (Figure #5)
1.   Loosen the knob and rotate the Flapper Retainer 
(720258.10) to allow the Inlet Flapper to be lifted 
upward.  
2.   With the Inlet Flapper held upward, install the Hose 
Assembly by inserting the flange of the Hose Flange 
Assembly into the space (gap) between the face of 
the Inlet Assembly Flange and the back face Flange 
Retainer Plate as shown.  The pin located in the upper 
right corner of the Inlet Assembly Flange will prevent 
the Hose Flange Assembly from sliding out of  
this pocket.
3.   Since the Hose Assembly may be rotated 360 
degrees, orient the Intake Nozzle to your preferred 
position and lock it in place.
4.   To lock the Hose Assembly in place, tighten the two 
knobs attached to the Flange Retainer Plate and 
Flapper Retainer as shown.  By tightening the knobs, 
it will push the flange of the Hose Flange Assembly 
against the flange of the Inlet Assembly and activate 
the Safety Switch Plate (720234.17).  THIS MUST BE 
DONE TO OPERATE THIS UNIT. 
5.   When the Hose assembly is removed from the Inlet 
Assembly for unit transportation, the Inlet Flapper must 
be closed and the Flapper Retainer (720258.10) must 
be rotated to lock it in place.
FIGURE #5
INLET
FLAPPER
INLET
ASSEMBLY
PIN
KNOB
FLAPPER
RETAINER
HOSE 
FLANGE
ASSEMBLY
HOSE 
ASSEMBLY
FLANGE 
RETAINER PLATE