Lightwave Communications USB SuperSwitch Manuel D’Utilisation

Page de 25
Lightwave Communications 
USB
 
S
ERVER
S
WITCH
 
www.lightwavecom.com 
 
Page 25 of 25
8. When the USB ServerSwitch has received the entire file, it will 
prompt the user through the serial port to confirm that the file is 
correct. Check the file version to be certain that it is the version that 
you wish to upload to the USB ServerSwitch system.  
9. When ready to modify the flash, select 'y' for 'continue with 
programming'.  NOTE:  DO NOT TURN THE POWER OFF at this 
point. 
 
10. The flash memory will be erased, and the new flash file will then be 
saved.  
11. You will get a prompt stating "Flash Programming Complete" after 
less than a minute. Finally, it will state "Starting System".  
12. 
After you see the Starting System prompt, the Flash update is 
completed, and the USBSS is ready to go. Simply disconnect your 
PC from the CONTROL IN port, and return all connections to normal.  
 
13. To verify that the System Flash has been updated, go to the Main 
Menu, select the System Setup screen and see the version number 
as listed on the screen.  
14. 
You may also verify the System Flash version by pressing and 
holding both front panel buttons for more than 3 seconds. The front 
panel display will change to a diagnostic mode (during which time the 
system in inoperative) and list the system firmware version. You 
MUST exit this diagnostic mode by pressing both front panel buttons 
for more than 3 seconds again, in order to return the unit to service.  
 
Start XMODEM transfer of USB ServerSwitch flash memory 
c c c c c c c c c c  
Received: USB ServerSwitch   v2.04 
Continue with programming? (y/n)  y 
 
Erasing the flash (takes about 10 sec.) 
Programming FLASH ........................................................... 
Flash programming complete. 
Starting System.