Lemur Monitors Jazzmutant Lemur Manuel D’Utilisation

Page de 122
The Lemur User Manual 
97 
 
key: 
Dial in the MIDI note number. If the value is a vector the second field will be extrapolated 
automatically. You can always override this setting by putting in your own value. 
pressure: 
The Variable chosen from the Variable menu that is converted to key pressure values is 
shown here. 
Scale: 
Type in the desired target scaling for the MIDI messages. Possible values range from 0 to 
127. 
Channel: 
Dial  in  the  MIDI  channel.  If  the  value  is  a  vector  the  second  field  will  be  extrapolated 
automatically. You can always override this setting by putting in your own value. Possible 
values range from 0 to 16. 
6.1.1.4. 
B0 – Control Change 
The Control Change data is used to produce pseudo-continuous data (ranging from 0 
to 127).   
 
controller: 
Dial  in  the  MIDI  controller  number.  If  the  value  is  a  vector  the  second  field  will  be 
extrapolated  automatically.  You  can  always  override  this  setting  by  putting  in  your  own 
value. Possible values range from 0 to 127 
value: 
The Variable chosen from the Variable menu that is converted to the controller values is 
shown here. 
Scale: 
Type in the desired target scaling for the MIDI messages. Possible values range from 0 to 
127. 
Channel: 
Dial  in  the  MIDI  channel.  If  the  value  is  a  vector  the  second  field  will  be  extrapolated 
automatically. Possible values range from 0 to 16. 
6.1.1.5. 
C0 – Program Change 
Used to change the patch number of synthesizers.