Set all values to default. Default values are shown in
dialog on page 160.
Select (NO/YES, alpha-numeric/numeric input, ON/
OFF).
Confirm displayed parameter and continues with the
"TRAVERSE MENU".
Dual-face Measurement
In the dual-face mode, the program will prompt for
measurements in both faces. When both measurements
are taken, the program will check the difference
between the two. If the difference in angle is within 27'
(0.5 gon)
 and the difference of two measured distances
is within 0.5 m (1.64 ft), the observations will be
averaged. These tolerances are used to avoid errors in
target identification. If exceeded an error message will
be displayed.
TRAV\ MULTIPLE MEAS
14:03
MC
MEAS
CLEAR  REC
TARGT ACCEP
ØV
:
103°45'25"
ØSlope Dist
:
50.125
m
Point no.
:
500
No. of Meas
:
1
σ
HZ
:
0°00'30"
σ
V
:
0°00'22"
σ
Slope Dist
:
0.001
m
ØHz
:
45°00'52"
F1
F2
F3
F4
F5
F6
HELP
Multiple Measurement
The measurement to a point can be repeated as often as
desired to achieve a higher accuracy or reliability. The
mean value of the measurements and the respective
standard deviation is displayed.