Leica TPS - System 1000 1000Z01 Manuel D’Utilisation

Page de 347
30
TPS-System 1000 Programs-2.3.1en
© Leica
OH
Measure Mode
This dialog is similar to the TPS 1000’s basic "Measure
Mode" dialog. Once a measurement is taken, the
program will return to the dialog "Target Point" to
acquire the next point for measuring.
If the orientation correction can be calculated
successfully from any of the first measurements, the
Hz and 
V values are displayed for further entered
target point. Motorized theodolites will automatically
drive the telescope to the target point.
Simultaneously measure and record data on the active
recording device. Return to the dialog "Target Point".
Measure a distance.
Record the measurement on the active recording device.
Return to the dialog  "Target Point".
Enter target data. For further information, please refer
to chapter "Measure & Record" described in the
"System" - user manual
.
Change the theodolite face.
Call up the CODE function, as described in chapter
"Measure & Record" described in the "System" - user
manual
.
Exit the program.
Accept the measurement and return to the dialog
"Target Point".
ORINT\ MEASURE MODE (GSI)
14:03
ALL
DIST
 REC
TARGT
F1
F2
F3
F4
F5
F6
Point no.
:
1
Hz
:
216°55'50"
V
:
71°16'20"
Refl.Height :
1.300
m
Slope Dist. :
385.231
m
Hz
:
-----
HELP
I<>II
MC