Leica TPS - System 1000 1000Z01 Manuel D’Utilisation

Page de 347
56
TPS-System 1000 Programs-2.3.1en
© Leica
IV
EL
AH
OH
BS
TD
Displays date and version of the running application.
Set the values to default. Default values are displayed in
dialog on page 55
.
Exit the program.
Store the current configuration and proceed to the
dialog "MEASURE MODE".
Dual-face Measurement
In the dual-face mode, the program will prompt for
measurements in both faces. When both measurements
are taken, the program will check the difference
between the two. If the difference in angle is within 27'
(0.5 gon)
) and the difference of two measured distances
is within 0.5 m (1.64 ft), the observations will be
averaged. These tolerances are used to avoid errors in
target identification. If exceeded an error message will
be displayed.