Lennox MPE-36R Manuel D'Instructions

Page de 18
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
THIS APPLIANCE HAS HOT AND ARCING 
OR SPARKING PARTS INSIDE.  DO NOT 
USE IT IN AREAS WHERE GASOLINE, PAINT 
OR FLAMMABLE LIQUIDS ARE USED OR 
STORED.  
THIS FIREPLACE SHOULD NOT BE USED 
AS A DRYING RACK FOR CLOTHING, NOR 
SHOULD CHRISTMAS STOCKINGS OR OTHER 
DECORATIONS BE HUNG NEAR IT.
USE THIS APPLIANCE ONLY AS DESCRIBED 
IN THIS MANUAL.  ANY OTHER USE IS NOT 
RECOMMENDED BY THE MANUFACTURER 
AND MAY CAUSE A FIRE, ELECTRIC SHOCK 
OR INJURY TO PERSONS.
IF APPLIANCE IS TO BE DISCONNECTED, TURN 
OFF CONTROLS FIRST.
DO NOT INSERT OR ALLOW FOREIGN 
OBJECTS TO ENTER ANY VENTILATION OR 
EXHAUST OPENING, AS THIS MAY CAUSE 
AN ELECTRIC SHOCK, FIRE, OR DAMAGE TO 
THE APPLIANCE.
SAVE THESE INSTRUCTIONS.
Figure 1
Table 1
TOOLS AND BUILDING SUPPLIES
NORMALLY REQUIRED
Tools:
 Phillips 
Screwdriver
 
7/16" Socket Drive
 Hammer
 
Saw And/or Saber Saw
 Level
 Measuring 
Tape
 Plumb 
Line
 
Electric Drill And Bits
 Pliers
 Square
 Gloves
Building Supplies:
 Framing 
Materials
 
Wall Finishing Materials
 Caulking 
Materials 
  
(noncombustible)
IMPORTANT NOTE: This fi replace system 
is not diffi cult to install. However, in the 
interest of safety, it is recommended that 
the installer be a qualifi ed or certifi ed 
“tradesman” familiar with commonly 
accepted fi replace installation and safety 
techniques as well as prevailing local 
codes.
LOCATING YOUR MERIT PLUS ELECTRIC 
FIREPLACE
Your new fi replace may be installed into existing 
framing or built into a wall (see Figure 1), or 
set in a freestanding mantel cabinet available 
from your dealer (see page 17).
When choosing a location for your new fi re-
place, ensure that the general instructions are 
followed.  Also, for the best effect, install the 
fi replace out of direct sunlight and away from 
overhead lighting.  See Figure 1.
GENERAL INFORMATION
Power Supply Wire Specifi cations
120 Volt, 60 Hz, 1600 Watts:
(ref. page 10)
Use two conductor, non-metallic sheath cable 
with ground wire for the incoming power 
supply.  The wire used must conform to local 
and national electrical codes for the specifi ed 
power consumption rating. See Table 1.
240 Volt, 60 Hz, 3000 Watt:
(ref. page 11)
Use three conductor, non-metallic sheath 
cable with ground wire for the incoming power 
supply. The wire used must conform to local 
and national electrical codes for the specifi ed 
power consumption rating. See Table 1.
Top View Showing Approved 
Room Locations of Fireplace
fi replace shown in gray.
Voltage
 
Wire Gage 
 
 
5 Volts
18 Gage 
Wall Switch/Thermostat Wire Gage
Voltage
Wire Gage 
Fuse Rating
120 V
240 V
20 AMP
15 AMP
14 GA.
14 GA.
Power Supply Wire Gage
Wall Switch or Wall Thermostat Kits
(optional kits, see page 17)
Low voltage wire is provided for the wall switch 
connection.  The wires gage requirements are 
shown on Table 1.