Technical Features
Preset Modes
No.
1
2
3
4
5
6
7
8
9
10
Resolution
(dots 
×
 lines)
640 
×
 480
640 
×
 480
800 
×
 600
800 
×
 600
1024 
×
 768
1024 
×
 768
1280 
×
 1024
1280 
×
 1024
1600 
×
 1200
1600 
×
 1200
Horizontal
Frequency
31.5 kHz
43.3 kHz
46.9 kHz
53.7 kHz
60.0 kHz
68.7 kHz
80.0 kHz
91.1 kHz
93.8 kHz
106.3 kHz
Vertical
Frequency
60 Hz
85 Hz
75 Hz
85 Hz
75 Hz
85 Hz
75 Hz
85 Hz
75 Hz
85 Hz
Graphics
Mode
VGA
VESA
VESA
VESA
VESA
VESA
VESA
VESA
VESA
VESA
Displaying the Monitor’s
Information
You can display the model name, serial number and year of
manufacture using the monitor‘s INFORMATION OSD.
Press and hold the 
 button for 3 seconds.
The INFORMATION OSD appears.
Example:
The INFORMATION OSD includes the model name, serial
number, and manufactured year.
The OSD automatically disappears after about 30 seconds.
MODE L : I BM P 9 6
SER NO : 1 2 - 3 4 5 6 7
MANUF ACTURED : 1 9 9 9 - 5 2
I NFORMA T I ON
Warning Messages
If no pictures appears on the screen, one of the following
messages appears on the screen. To solve the problem, see
“Troubleshooting” on page 18.
The input signal condition
OUT OF SCAN RANGE
indicates that the input signal is not supported by the
monitor’s specifications.
NO INPUT SIGNAL
indicates that no signal is input.
MONITOR IS IN POWER SAVE MODE
indicates that the computer is in power saving mode.
Thes message is displayed only when your computer is
in a power saving mode and you press any one of the
buttons on the monitor.
The selected connector
This message shows the currently selected connector
(INPUT 1 or INPUT 2).
INFORMATION
OUT  OF  SCAN  RANGE
INPUT 1
Technical Features
Additional Information