HP RC3000 Manuel D’Utilisation

Page de 143
RC3000 Antenna Controller 
Chapter 3 
Detailed Operation 
 
 117  
 
3.3.1.3.11 SHAKE 
 
AZ 1: -40.0 2:  50.0 3:   0.0 CONF-SHAKE 
EL 1:  30.0 2:  40.0 3: -67.5 CYCLE: 100 
PL 1: -10.0 2:  10.0 3:   0.0 DELAY:  15 
MOVE 1 AZIM <-180.0/180.0> 
 
AZ #:   
 
MOVE # AZIM <-180.0/180.0> 
The AZ field allows the user to specify the azimuth target for moves 1, 2 or 3. 
EL #:   
 
MOVE # ELEV <-90.0/90.0> 
The EL field allows the user to specify the elevation target for moves 1, 2 or 3. 
PL #:   
 
MOVE # POL <-180.0/180.0> 
The PL field allows the user to specify the polarization target for moves 1, 2 or 3. 
CYCLE: 
 
NUMBER OF SHAKE CYCLES <1-9999> 
The CYCLE field allows the user to specify the total number of movement cycles the SHAKE function will 
perform. 
DELAY:   DELAY 
<0-999 
SECONDS> 
The DELAY field allows the user to specify the amount of time (in seconds) that the SHAKE function will 
wait between “moves”.  Specifying a value of 0 will cause no delay between “moves”.