80 Device Programming Menu Mode
 
 
The following explains these prompts in detail. The left two columns identify the prompts and list the 
available entries. The right-most column provides a further explanation of the entries. 
Note: Entering a number other than one specified will give unpredictable results. 
 
 
          80
 
Powerline Carrier Device 
programming
 
0 = exit mode 
1 = enter mode 
 
Entering “1” advances to the next prompt below. 
Entering “0” exits mode, upon which this prompt blinks, indicating the 
mode is inactive.  
 
 A 
0I
 
Device number 
01-08 =  device number to be programmed 
[✻] = continue 
00 = exit Device Programming mode 
 
Enter device numbers as 2-digit entries. 
 
 
  b 
aa
 
Device action 
0 = No response 
1 = Close for 2 seconds  
2 = Close and Stay Closed 
3 = Continuous Pulse on & off  (1 sec ON, 1 sec 
OFF) 
[✻] = continue 
[#] = return to previous prompt
 
Enter the 1-digit action (0-3) for the device being programmed (current 
action is displayed). 
NOTES:  
1.  If  “3” is entered (pulse), only up to 3 different devices can be pulsed 
if one of the devices is a siren/horn (X-10 Powerhouse Security 
model SH10A). In addition, the siren/horn cannot be manually 
activated using the lights on/lights off keypad commands. 
2.  If using an X-10 Powerhouse Security SH10A siren: 
 
• you must use device action “3.”  
 
• you must change the device action default to “3” if using default  
 
   table 2 or 4  
 
 
 C 
et
 
Start event type 
0 = Not used   
3 = Trouble 
1 = Alarm  
[✻] = continue 
2 = Fault 
[#] = return to previous 
prompt 
 
Enter the 1-digit event type (0-3) to activate the device being 
programmed. A zone list must be used in conjunction with an event. If 
a zone type/system operation is to be used instead of an event, enter 
“0”. 
 
 
 
d
 
zl
 
Start zone list 
1-3 = zone list number (to be programmed in 
field ✻81)  
0 = zone list not used for this device 
[✻] = continue 
[#] = return to previous prompt 
 
If a zone list will be used to start the device action, enter the zone list 
number at this prompt. 
 
 
 E 
zt
 
Start zone type 
01-58 = zone type to start this device action 
 
(select only those that are applicable) 
00 = zone type not used for this device 
[✻] = continue 
[#] = return to previous prompt
 
 
If a zone type or system operation will be used to start the device 
action, enter the appropriate 2-digit code for the device being 
programmed (see table that follows). 
Choices for zone types 
00 = Not Used 
04 = Interior Follower 
08 = 24 Hr Aux 
01 = Entry/Exit #1 
05 = Trouble Day/Alarm Night 09 = Fire 
02 = Entry/Exit #2 
06 = 24 Hr Silent 
10 = Interior w/Delay 
03 = Perimeter 
07 = 24 Hr Audible 
24 = Silent Burglary
 
Choices for system operation 
20 = Arming–Stay 
33 = Any Alarm (except zt 08)  42 = Sys. Batt. Low 
21 = Arming–Away 
36 = At Bell Timeout** 
43 = Comm. Failure 
22 = Disarm. (Code + OFF)  38 = Chime 
52 = Kissoff 
31 = End of Exit Time  39 = Any Fire Alarm 
58 = Duress 
32 = Start of Entry Time 
40 = Bypassing 
** Or at Disarming (which ever occurs earlier) 
 
Note: If an X-10 device has been programmed to ZT05 or ZT07 and *55 
has been enabled, the device response will be dependent upon the 
selection made in *55 Field "Ln". 
 
 
 F 
zl
 
Stop zone list 
1-3 = zone list to stop this device action 
0 = zone list not used 
[✻] = continue 
[#] = return to previous prompt 
 
If a zone list will be used to STOP, or restore, the device action, enter 
the zone list number 1, 2, or 3 (to be programmed in 
81 mode). If not 
used, enter “0”. 
 
 
 IA 
zt
 
Stop zone type 
01-58 = zone type to start this device action 
 
(select only those that are applicable) 
00 = zone type not used for this device 
[✻] = continue 
[#] = return to previous prompt
 
If a zone type or system operation will be used to STOP the device 
action, enter the appropriate 2-digit code (see the "ZT" choices listed 
above). If not, enter 00. 
The display then returns to the DEVICE NUMBER prompt (A) so that 
you can enter the next device number to be programmed, or enter [0][0] 
to end device programming.