Honeywell ADEMCO LYNXR Series Guide De Montage

Page de 72
 
– 71 – 
INCOMING
PHONE
LINE
T
O HANDSET
PHONE
LINE
W
ARNING:
T
O PREVENT
RISK OF
SHOCK
DISCONNECT
TELEPHONE
LINE A
TELECOM
J
A
CK BEFORE
SER
VICING
THIS UNIT
.
WEEKL
Y TESTING 
IS
REQ
UIRED T
ENSURE
PR
OPER OPERA
TION
OF THIS 
SYSTEM
ALL OUTPUT
CIRCUITS
ARE PO
WER
LIMITED
PREMISES
TELEPHONE
2k OHMS
EOLR 
1
2
3
4
8
6
5
11
7
10
12
15
16
13
14
PHONE
ZONE
SOUNDERS
PLCD
AC
PLUG-IN
TRANSFORMER
9V
A
C
, 15V
A
EAR
TH
GR
OUND
EAR
TH
GR
OUND
HARD
WIRED
ZONE
INCOMING
TELEPHONE
LINE
RING
TIP
RING
TIP
( )
( )
(+)
(+)
( )
(+)
T
O 24HR 110V
A
C
UNSWITCHED
OUTLET
PIEZO
6-14VDC
120mA max.
(e
.g.
 W
A
VE2EX)
6-14VDC
30mA max.
D
ATA
OUT
SYNC
IN
POWERLINE
CARRIER DEVICES
TRIGGER SIGNAL (NEG)
RJ11
8
POSITION
JA
C
K
AC
AC
SYNC
COM
D
ATA
9
BELL
01009-016-V0
THIS DEVICE COMPLIES 
WITH P
AR
T 15 OF FCC R
ULES
.
OPERA
TION IS SUBJECT 
T
THE FOLLO
WING 
TW
O
CONDITIONS:
 (1) 
THIS DEVICE MA
Y NO
T CA
USE
HARMFUL INTERFERENCE, AND (2) 
THIS DEVICE MUST
A
CCEPT ANY INTERFERENCE RECEIVED
, INCLUDING
INTERFERENCE 
THA
T MA
Y CA
USE UNDESIRED
OPERA
TION.
THIS EQ
UIPMENT SHOULD BE INST
ALLED IN
A
CCORD
ANCE 
WITH 
THE NA
TIONAL FIRE PR
O
TECTION
ASSOCIA
TION'S ST
AND
ARD 72, CHAPTER 2 (NA
TIONAL
FIRE PR
O
TECTION ASSOC
., BA
TTER
YMARCH P
ARK,
Q
UINICY
, MA 02269).
PRINTED INFORMA
TION DESCRIBING PR
OPER
INST
ALLA
TION, EV
A
CU
A
TION PLANNING AND
REP
AIR SER
VICE IS 
T
O BE PR
O
VIDED 
WITH 
THIS
EQ
UIPMENT
.
1332X10 ONL
Y
CONNECTIONS
FCC ID:
 CFS8 DLL
YNX (L
YNXR/L
YNXR24) AND 
CFS8DLL
YNXREN-1 (L
YNXR-EN) COMPLIES 
WITH
FCC R
ULES
, P
AR
T 68 FCC REGISTRA
TION
No
. 5GB
USA-25623-AL-E RINGER EQ
UIV
ALENCE:
 0.6B
1332/1332X10/1332CN
CONNECTIONS
NO
TE
USE ONL
Y
1332/1332X10
OR 1332CN
TRANSFORMERS
PR
O
VIDED
L
YNXR SERIES SUMMAR
Y OF CONNECTION
LOCAL SOUNDER
DISABLE SHUNT
REMO
VE T
DISABLE
THE L
YNX SERIES CONTR
OLS ARE EQ
UIPPED 
WITH
AN INTEGRAL RECHARGEABLE BA
TTER
Y P
A
CK.
AA
V / LRR
TRIGGER
(L
YNXR/L
YNR24)
LRR
TRIGGER
(L
YNXR-EN)
REPLA
CE EVER
Y FOUR 
YEARS
LYNXR:
             P/N L
YNXRCHKIT
-SC
LYNXR24:
         P/N L
YNXRCHKIT
-HC
LYNXR-EN:
       P/N L
YNXRCHKIT
-SC
                                                       OR
                         P/N L
YNXRCHKIT
-HC
 
NOTE:  Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the 
approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police 
emergency number. 
 
 
The System must be checked by a qualified technician once every three years.