Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0 Manuel D’Utilisation

Page de 70
 
 
Orifice Assembly 
The orifice assembly contains a set of poppets and orifice plates. Fuel 
flow is metered between the INLET port chamber and OUTLET port 
chamber in proportion to the poppet position and resultant flow area. 
The poppet assembly is connected to the extension rod of the actuator. 
As the actuator retracts, the poppet assembly retracts to increase the flow 
area between the poppets and the two orifices. As the actuator extends, 
the poppet assembly extends to reduce the fuel exposure from the INLET 
port chambers to the two orifices. When the actuator is fully extended, the 
poppets seat in the orifices to close the valve. See Figure 2-3. 
 
Soft Seats 
The orifices contain pressure-energized soft seats and metal-to-metal 
hard seats, which provide a leak-tight seal when the poppets are in a 
closed position. See Figure 2-3. 
Return Spring 
A pre-loaded, fail-safe spring is located between the valve housing and 
poppet assembly. The spring load increases as the valve opens. If a 
power failure occurs, the spring causes the poppets to return to the soft 
seats, thereby closing the valve. See Figure 2-3. 
 
 
 
CH. 2: UNDERSTANDING THE HFG2.0 
33