Hampton Direct H200 Manuel D’Utilisation

Page de 32
Hampton H200 Cast Freestanding Woodstove
4
This is a copy of the label that accompanies 
each Hampton H200 Freestanding Woodstove. 
We have printed a copy of the contents here 
for your review.
SAFETY LABEL
NOTE: Hampton units are constantly being 
improved. Check the label on the unit and if 
there is a difference, the label on the unit is the 
correct one.
HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
DO NOT REMOVE THIS LABEL
290
CERTIFIED TO COMPLY WITH JULY 1990
PARTICULATE EMISSION STANDARDS.
UNITED STATES  ENVIRONMENTAL
PROTECTION  AGENCY
MADE IN CANADA
CAUTION
918-428
LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO
SUITABLE FOR MOBILE HOME INSTALLATION
MODEL:  HAMPTON  CAST FREESTANDING WOOD STOVE -  H200
TESTED TO: UL 1482 / ULC S627
REPORT NO: 219-S-09-2
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS
RESIDENTIAL INSTALLATION USING
 SINGLE WALL  CONNECTOR
SIDEWALL
A 431 mm / 17 in
D 737 mm / 29 in
BACKWALL
B 381 mm  / 15 in
E 435 mm / 17-1/8 in
CORNER
C 330 mm / 13 in
F  505 mm / 19-7/8 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR -  MOBILE HOME
SIDEWALL
A 381 mm / 15 in
D 686 mm / 27 in
BACKWALL
B 254 mm  / 10 in
E 308 mm / 12-1/8 in
CORNER
C 228 mm / 9 in
F 403 mm / 15-7/8 in
SIDEWALL
A 381 mm / 15 in
D 686 mm / 27 in
BACKWALL
B 254 mm  / 10 in
E 308 mm / 12-1/8 in
CORNER
C 228 mm / 9 in
F 403 mm / 15-7/8 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
MINIMUM ALCOVE CEILING HEIGHT: 1.5 M / 5 FT         MAXIMUM ALCOVE DEPTH 1220 MM / 48 IN.
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 457 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
FLOOR
PROTECTION*
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103
HT FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A
CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE
WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT
COMBUSTION AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY.
DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU
ARE OVERFIRING.  INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR
RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE GLASS ONLY WITH NEOCERAM GLASS.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS
INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA:
LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100, SUPER VENT 2100, SUPERPRO 2100, CF SENTINAL.
IN USA:   LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL
DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL.  CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL
S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD,
AMERI-TECHS,  ICC EXCEL 2100, SIMPSON DURA PLUS HTC .  USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
MEASURE
FLUE
FROM
        HEATER
        CENTER-LINE
MANUFACTURED BY:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC  V4G 1H4
SIDEWALL
G 381 mm / 15 in
I 686 mm / 27 in
BACKWALL
H 330  mm / 13 in
J 384 mm / 15-1/8 in
290
* In Canada, floor protection must extend
18" (457mm) to the front and 8" (200mm)
to each side and back of the stove.
K 457 mm  /  18 in
L 150 mm  /  6 in
M 150 mm  /  6 in
SIDE
S
IDE
FRONT
K
M
L
BACK
O
DEC
NOV
OCT
SEPT
AUG
JUL
JUN
MAY
APR
MAR
FEB
JAN
DATE OF MANUFACTURE
2005
2006
2007
SAFETY LABEL FOR H200