Grandstream Networks TV Converter Box HT386 Manuel D’Utilisation

Page de 34
 
Grandstream Networks, Inc. 
HT-386 User Manual 
Page 20 of 34  
 
Firmware 1.0.3.64 
Last Updated:  2/2007
 
T
ABLE 
8:
  
HT-386
 
B
ASIC 
S
ETTINGS 
P
AGE 
D
EFINITIONS
 
End User 
Password 
This contains the password for end user to access the Web Configuration 
Menu. User can put new password here. This field is case sensitive with 
maximum of 25 characters 
Web Port 
This is the device’s internal HTTP server port. Default is 80. 
 IP Address 
- If DHCP mode is enabled, then all the field values for the Static IP mode are 
not used (even though they are still saved in the Flash memory.) The HT-386 
will acquire its IP address from DHCP in the network. 
 
PPPoE settings is usually for DSL/ADSL modem users. The HT will attempt to 
establish a PPPoE session if PPPoE account is set.  
 
- If Static IP mode is selected, the IP address, Subnet Mask, Default Router IP 
address, DNS Server 1 (mandatory), DNS Server 2 (optional) fields need to be 
configured. 
DHCP hostname 
This option specifies the name of the client. This field is optional but may be 
required by some Internet Service Providers. Default is blank. 
DHCP domain 
This option specifies the domain name that client should use when resolving 
hostnames via the Domain Name System. Default is blank. 
DHCP vendor class ID 
This option is used by clients and servers to exchange vendor-specific 
information. Default is blank. 
Time Zone 
This parameter controls how the displayed date/time will be adjusted 
according to the specified time zone. 
Daylight Savings Time 
This parameter controls whether the displayed time will be daylight savings 
time or not. If set to “Yes” and the Optional Rule is empty, then the displayed 
time will be 1 hour ahead of normal time.  
 
The “Automatic Daylight Saving Time Rule” shall have the following syntax: 
start-time;end-time;saving 
Both start-time and end-time have the same syntax: 
month,day,weekday,hour,minute 
month: 1,2,3,..,12 (for Jan, Feb, .., Dec) 
day: [+|-]1,2,3,..,31 
weekday: 1, 2, 3, .., 7 (for Mon, Tue, .., Sun), or 0 which means the daylight 
saving rule is not based on week days but based on the day of the month. 
hour: hour (0-23), 
minute: minute (0-59) 
 
If “weekday” is 0, it means the date to start or end daylight saving is at exactly 
the given date. In that case, the “day” value must not be negative. If “weekday” 
is not zero and “day” is positive, then the daylight saving starts on the first 
“day”th iteration of the weekday (1st Sunday, 3rd Tuesday etc). If “weekday” 
us not zero and “day” is negative, then the daylight saving starts on the last 
“day”th iteration of the weekday (last Sunday, 3rd last Tuesday etc). 
 
The saving is in the unit of minutes. The saving time may also be preceded by 
a negative (-) sign if subtraction is desired instead of addition. 
 
The default value for “Automatic Daylight Saving Time Rule” shall be set to 
“04,01,7,02,00;10,-1,7,02,00;60” which is the rule for US.  
 
Examples