GE SX TRANSISTOR CONTROL IC3645SR4U404N2 Manuel D’Utilisation

Page de 74
ADJUSTABLE FEATURES 
SX TRANSISTOR CONTROLS
 
 
 
Page 
56
 
 
 
January 2000
   
Section 6.3  Set-up Function Procedures 
 
With the Handset connected, hold down the CONT key and 
turn on the key switch. This will place you in the set-up 
mode, ready to monitor or adjust control function settings. 
 
NOTE: The term “Push” means to depress key for 
approximately one second. 
 
Section 6.3.1  Setup Mode 
 
SET-UP MODE
Hold Down CONT
And Turn On Key
8 8 8 8
Segment Check
Displayed
ACTION
DISPLAY
SHOWS
REMARKS
Push Function Number
U 0 0 5
Selected Function No.
Is Displayed
After One Second
Time Delay
0 8 5
Stored Value For The
Function Is Displayed
Push CONT
0 8 5
Display Value
Will Blink
Change Value With
Adjustment Knob
Value Changes
While Blinking
Push STORE
125
New Value Stored And
Blinking Stops
Push ESC
8 8 8 8
Segment Check
Displayed
125
 
 
At this point, another function can be monitored/changed 
by pushing another function number, or the vehicle can be 
placed in the run mode by holding the ESC key down for 
one second or longer.  The display will return to either the 
diagnostics mode, the BDI display, or a blank display (if 
BDI is not used and there are no fault codes).  The vehicle 
can now be operated with the Handset connected, or the 
Handset can be disconnected before operation. 
 
NOTE: You can return to the segment check mode at any 
time, by holding down the ESC key until 8888 appears in 
the display.
 
 
Section 6.3.2  Status Code Scrolling 
 
The SX family of controllers furnishes a function register 
that contains the last 16 “stored status codes” that shut 
down vehicle operation (a PMT type fault that is reset by 
cycling the key switch) and the battery state of charge 
reading at the time the fault occurred. The first of the 16 
status codes will be overwritten each time a new status 
code occurs. This stored status code register can be 
cleared from memory by using the Handset. 
 
Key Switch Off
Push ESC and CONT
At The Same Time
Release ESC and CONT
Key
Status Code Displayed
Push CONT Key
Displays Battery
State-Of-Charge When
Fault Occurred
Push CONT Key
Display Hourmeter Reading
When Fault Occurred
Push CONT Key
Push CONT Key
ACCESSING STORED STATUS CODES
WITH GE HANDSET
Section 6.3.3  SX Family Handset, Plug  
Connections and Outline Drawing 
 
“Y” Plug 
            
 
Handset Cable Part Number  - 325B1002G1