Epson V7 Manuel D’Utilisation

Page de 344
5-30 
3. SHARP PLC
3.
SHARP PLC
Available PLCs
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series is as follows:
Select PLC 
Type
CPU
Unit/Port
Connection
PLC2Way
JW series
JW50, JW70, JW100
JW50H, JW70H
JW100H
ZW-10CM
JW-10CM
RS-422
[Wiring Diagram 4]
JW20
JW-31CUH
JW-21CM
RS-422
[Wiring Diagram 4]
JW100/70H
COM port
JW70CU/JW100CU
JW70CUH, JW100CUH
Communication port on 
the CPU unit
RS-232C [Wiring Diagram 1]
JW20
COM port
JW22CU
RS-422
[Wiring Diagram 3]
JW-32CUH
JW-33CUH
Communication port 1 
on the CPU unit
Communication port 2 
on the CPU unit
RS-232C
PG/COMM2
[Wiring Diagram 2]
RS-422
PG/COMM1
[Wiring Diagram 5]
PG/COMM2
[Wiring Diagram 5]
Item
Setting on PLC
V7 Comm. Parameter Setting
Baud rate
19200 bps
19200 bps
Port
0 for STA.NO 
×10, 1 for STA.NO ×1
1
Parity
Even
 Even
RS-422
4-wire system (fixed)
Data length
7
7
Stop bit
2
2
Error check
Sumcheck (fixed)
Transmission mode
Command mode (fixed)