4. Remote Mount Electronics Option.  Due to 
process temperature, vibration or accessibility 
the housing/electronics of the LTM transmitter 
can be remote mounted as far as 25 ft.  The 
housing/electronics are supplied with a pipe-
mount bracket that can be mounted most 
nearby posts or pipes with hose clamps.  The 
drawing below depicts a gage mounted 
transmitter in the top mount remote electronics 
configuration.
Figure 12.  Gage mount transmitter in the top mount remote 
electronics configuration.
NEVER install the sensor probe inside an 
insulation blanket that may be around the 
level gage.  This will overheat the sensor probe 
and cause failure.
NEVER bend, bow or cause a kink in the 
sensor probe, this will damage the instrument 
and void the warranty.  Do not attempt to 
straighten the sensor probe, this will not help 
the instrument work.  If the shipment arrives 
damaged please file a claim with the shipping 
company and contact the factory to arrange for 
a replacement.
There are a variety of ways to install a 
standalone transmitters (i.e. crane, lift, etc…), 
the basic rule to remember when installing an 
LTM transmitter is DO NOT DAMAGE the 
sensor probe, this will void the warranty.  If 
damage is suspected please contact the factory 
and be prepared to provide pictures.
In REMOTE MOUNT electronic options 
please support the sensor probe at the 
elbow/condulet and then every 3 feet 
(depending on length of cable).  Support at 
every 2 feet may be required if explosion proof 
conduit is utilized by the end user.