Emerson Transmitter 350 Mode D’Emploi

Page de 35
Section
6
Transmitter Specifications
6.1 Hazardous Locations /              
       General Ratings
CSA and CSAUS:  Explosion Proof:
Class I Div. 1 or 2, Grps. B, C, D                                                
Class II, Grps. E, F, G                                                                  
Class III                          
T
amb
-40°C to 85°C (-40°F to 185°F)
ATEX:  Ex d:
Sira 10ATEX1308X
Ex d IIC T5 Gb
Ex tb IIIC T100°C IP66 Db
T
amb
-40°C to 85°C (-40°F to 185°F)
0344  
II 2GD
IECEx: Ex d:
IECEx SIR 10.0150X
Ex d IIC T5 Gb
Ex tb IIC T100°C IP66 Db
T
amb
-40°C to 85°C (-40°F to 185°F)
6.2 Electronic Specifications
Supply Voltage:
13 – 36 Vdc (13V @ 20mA)
Repeatability:
.005% of full scale or                                                                 
.010”, whichever is greater
Non-Linearity:
.01% of full scale or .030”, 
whichever is greater
Sensor Accuracy:            .01% of full scale or .030”, 
whichever is greater
Damping:
1 to 26 seconds 
Operating Temp:
-50 to 85 C
(-58 to 185 F)
Housing:
Explosion proof, dual compartment, 
½”npt conduit, epoxy coated 
aluminum; NEMA 4X, 7
Humidity Limits:
SAMA PMC 31.1-5.2
Vibration Limits:
SAMA PMC 31.1-5.3
RFI Limits:
SAMA PMC 31.1-
20 to 1000 MHz 
Up to 30 V/m
6.3 Sensor Probe Specifications
Material:
5/8” 316ss standard, optional: 
Hastalloy, Monel, or Kynar sleeved
Operating Temperature:
-50 to 149 C 
(-58 to 300 F)
Maximum Pressure:
2000psig @ 300F
Range:
12 in. to 30 ft.
14