Emerson Transmitter 350 Mode D’Emploi

Page de 35
Section
2
Transmitter Overview
2.0 General Description
The LTM-Series are 2-wire electronic field 
instruments, suitable for installation in hazardous 
and non-hazardous locations.  Testing and 
certification has been obtained from different 
agencies for installation in such areas.  This 
instrument is designed to measure and transmit an 
analog and/or digital signal proportional to liquid 
level in a tank.  The complete assembly includes an
explosion-proof enclosure and attached sensor tube 
and a magnetic float.  The LTM-Series are available 
in a variety of lengths and wetted materials to 
accommodate many different applications.
2.1 Product Identification
Figure 1. Example   label/name plate
The product can be identified by the stainless steel 
label that is located on the side of the transmitter 
enclosure/housing.
The label can be read as follows:
wwww = Any hazardous location area classification 
markings that the instrument is approved for.
ZZ/ZZ = Born on date; the2 digit month and 2 digit 
year the instrument was shipped to the customer.
AAAA = The specific serial number assigned by 
Magtech for complete traceability.
BBBB = The overall probe length of the instrument.
    Note:  THIS IS NOT THE MEASURING RANGE.
XXXX = The measuring range of the instrument.  
The 0 and 100% (4/20mA) output range.
YYYY = The end user specified tag number (only 
when specified).
2.2 Transmitter Configurations
LTM-Series transmitters generally have two 
configurations:
1. Gage Mounted:  Where the transmitter is
mounted on the outside of a magnetic level 
gage and strategically located within a 
certain longitudinal distance from the 
transmitter sensor probe and a magnetic 
float is placed inside the level gage.
2. Standalone (or Direction Insertion Type):  
Where the transmitter has a magnetic float 
directly around the transmitter sensor 
probe and the probe is directly inserted into 
a tank/vessel.
In either configuration as the tank level changes, 
the float tracks the change and continuously 
activates the sensor probe.  The electronics process 
the change in signal and output an analog and/or 
digital signal.  This output is precisely the liquid level 
in the tank.
Magtech is always willing to explore 
unique applications that require their own 
distinctive configurations.  Please consult the 
factory for guidance.
2
wwwwwwwwwwwwwwwwwwwwwww
ZZ/ZZ
S/N  AAAA / OL  BBBB
            MODEL  LTM- 350-G-XXXX
              TAG  YYYY
ISE-MAGTECH
wwwwwwwwwwwwwwwwwwwwwww
wwwwwwwwwwwwwwwwwwwwwww