Clearances: When facing the front of the fireplace heater the
minimum clearances to combustible construction (material) are
the following:
Open in front to provide service, access, and clearance to
Open in front to provide service, access, and clearance to
construction.
Top of appliance (ceiling)
Top of appliance (ceiling)
36 (inches)
Draft Diverter to Rear Wall
2 (inches)
Side Wall
6 (inches)
Heater Corners (45° angle) to Wall
4 (inches)
Floor
0 (inches)
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or
other combustible material, other than wood flooring, the appli-
ance shall be installed on a metal or wood panel extending the
full width and depth of the appliance.
The base referred to above does not mean the fire-proof base as
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is primarily for rugs that may
be extremely thick and light-color tile that can discolor.
(914mm) TO CEILING
OR HORIZONTAL
PROJECTION ABOVE
APPLIANCE
Figure 2
Figure 3
Figure 4
CLEARANCES