Clearances:  When  facing  the  front  of  the  fireplace  heater  the 
minimum clearances to combustible construction (material) are 
the following:
Open  in  front  to  provide  service,  access,  and  clearance  to 
construction.
Top of appliance (ceiling) 
36 (inches) 
Draft Diverter to Rear Wall 
2 (inches)
Side Wall   
6 (inches)
Heater Corners (45° angle) to Wall 
4 (inches)
Floor 
 
0 (inches)
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or 
other combustible material, other than wood flooring, the appli-
ance shall be installed on a metal or wood panel extending the 
full width and depth of the appliance.
The base referred to above does not mean the fire-proof base as 
used on wood stoves. The protection is primarily for rugs that may 
be extremely thick and light-color tile that can discolor.
(914mm) TO CEILING
OR HORIZONTAL
PROJECTION ABOVE
APPLIANCE
Figure 2
Figure 3
Figure 4
CLEARANCES