Furuno MU-17OC Manuel D’Utilisation

Page de 65
 
 
6
Port, cable and connectable equipment 
Used cable 
Port 
Name 
Name Type Code 
No. 
Standard/
Option 
Connectable 
Equipment 
TB-1 
Power 
cable 
14AWG-2C-PVC 
*5M* 
000-154-337
Standard Power 
source 
DVI-D 
DVI 
Cable 
DVI-D/D 
SINGLELINK5M
000-149-054
Option 
PC, 
FAR-21X7 series 
RGB1 
3COX-2P-6C 
5M 
000-146-500
Option 
RGB2 
Analog 
RGB 
Cable 
3COX-2P-6C 
10M 
000-146-501
Option 
FCV-1200L/1200LM, 
CH-250, CH-270, 
CSH-5L/8L, 
FSV-24/24S, 
GD-280/380/680, 
FR-1500 MK3 series,   
FR-21X5 series,   
NavNet vx2 
VIDEO1 
VIDEO2 
VIDEO3 
Prepare the following cable locally. 
▪ Connector type: RCA (metal), both ends 
▪ Cable length: Max. 10 m 
▪ 2.5C2V or 3C2V (Japan Industrial Standard, or the 
equivalent) coaxial cable (Impedance: 75 Ω) 
Conductor
S = 0.19 mm
 = 0.5 mm
2
Shield
Insulator
Vinyl
sheath
Cable 3C2V
 
Video cassette 
recorder, CCD camera, 
DVD player 
 
Grounding 
Fasten a ground wire (dockyard supply) and the gray crimp-on lug of the power cable to the 
ground terminal together. The length of the ground wire should be as short as possible. 
 
Note: Use a “closed-type” lug (
) to make the ground connection. Do not use an 
“open-type” lug (
).