Chapter 4 Rack and Optional Product Installation
4.2 Installable Racks
4.2 Installable Racks
ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning-
55
Copyright 2012 FUJITSU LIMITED
P3AM-5492-04ENZ0
Figure 4.1
Unit installation area
Table 4.2
Specifications for the unit installation area
■
Placement conditions
When determining service areas, refer to the installation document of the rack to be used.
Install air conditioning in order to ensure that the interior temperature of the rack satisfies the
temperature conditions listed in
Install air conditioning in order to ensure that the interior temperature of the rack satisfies the
temperature conditions listed in
and
.
Specification
Condition
(1)
Rack front space
(From the fixed part of the ETERNUS DX Disk storage
system on the front side to the inner side of the front
rack door)
(From the fixed part of the ETERNUS DX Disk storage
system on the front side to the inner side of the front
rack door)
40mm or more
(2)
Mount bracket length
(Size between each end of the front and rear rack
pillars)
(Size between each end of the front and rear rack
pillars)
630mm to 800mm
(3)
Rack space
(From the fixed part of the ETERNUS DX Disk storage
system on the front side to the inner side of the rear
rack door)
(From the fixed part of the ETERNUS DX Disk storage
system on the front side to the inner side of the rear
rack door)
830mm or more
(4)
Rack mount kit installation area
482mm or more (recommended)
ETERNUS DX
Disk storage system
Disk storage system
(1)
(2)
(3)
(4)
Rack rear door
Rack front door
Rack pillars
Rack rails