Contemporary Research 232-FMA Manuel D’Utilisation

Page de 14
Control Cable Connections
 
 
All drawings show pin numbers relative to a PC COM port or Axcent3 DB-9 RS-232 control port.  
Pin-outs to other types of control ports may vary. Pins 4 and 9 are momentary closures to GND (5). 
 
Single Tuner 
5  GND 
2  RXD 
3  TXD 
RXD   2 
GND   5 
TXD   3 
Control Wiring – Single Unit
9-pin D-sub 
female
RS-232
Control Port
Preset Up   4 
Preset Down   9 
 
Multiple Tuners, AV6x4 Router 
 
Up to three tuners can be daisy-chained from one RS-232 control port. Remember that you will need 
to use the Unit# address in your programming when you control more than one tuner from the 
same control port. You can also daisy-chain one or two tuners with an AV6x4 A/V Router. In this 
application, set the Router to the lowest Unit#. 
 
5  GND 
2  RXD 
3  TXD 
RXD   2 
GND   5 
RS-232 Wiring – Two Units
Unit 2
9-pin D-sub 
female
RS-232
Control Port
Unit 1
9-pin D-sub 
female
TXD   3 
GND   5 
TXD   3 
RXD   2 
 
5  GND 
2  RXD 
3  TXD 
RXD   2 
GND   5 
TXD   3 
RS-232 Wiring – Three Units
Unit 3
9-pin D-sub 
female
RS-232
Control Port
Unit 2
9-pin D-sub 
female
Unit 1
9-pin D-sub 
female
TXD   3 
GND   5 
GND   5 
TXD   3 
RXD   2 
RXD   2 
 
 
Contemporary Research 
 
 
 
11 
 
 
     
232-FMA FM Stereo Tuner