Ciprico Rimfire 3880 Manuel D’Utilisation

Page de 230
User’s Guide
21020285 D
Chapter 7   Board-control Commands
 
Board Information (15H)
 Page 7 - 35
Bus Throttle
This field displays the currently selected throttle option in an identical manner 
as the field used to select throttle in the General Options command. Possible 
values are shown below:
Engineering Revision
This field indicates the revision level used by Ciprico to identify its source code. 
This field is useful only for Ciprico and should not be used to identify the 
revision level of the board firmware.
Firmware Revision
This field contains a value that identifies the released level of Firmware for the 
product. 
Day, Month, Year 
These three fields, when combined, indicate the date (in hex) that the firmware 
in the EPROM was compiled.
Value
Represents
Number of Bytes per Burst
00H
2
0
1
01H
2
1
2
02H
2
2
4
03H
2
3
8
04H
2
4
16
05H
2
5
32
06H
2
6
64
07H
2
7
128
08H
2
8
256
09H
2
9
512
0AH
2
10
1024
0BH
2
11
2048
Table 93: Bus Throttle Field Values