Ciprico Rimfire 3880 Manuel D’Utilisation

Page de 230
21020285 D
User’s Guide
 Appendix A   Error Codes
Page A - 8 
Status Port Error Codes 
Code
Description
00H or FDH
The onboard processor is not working; it cannot access firmware EPROM; cannot 
access the Status Port.
04H
Static RAM error. All words of static RAM are written with FFFFH, then zero. 
This test is not exhaustive.
0CH
Firmware CRC error. The calculated CRC for odd and even EPROMs does not 
match the value stored in EPROM.
80H
SCSI PSI Address/Counter registers not masked to WORD boundaries.
84H
SCSI PSI Address/Counter registers no masked to DWORD boundaries.
88H
Value Miscompare errors of SCSI PSI R/W registers in Manual Load mode.
8CH
Value Miscompare errors of SCSI PSI R/W registers in Auto Load mode.
90H
VME PSI Address/Counter registers not masked to WORD boundaries.
94H
VME PSI Address/Counter registers not masked to DWORD boundaries.
98H
Value Miscompare errors of VME PSI R/W registers in Manual Load mode.
9CH
Value Miscompare errors of VME PSI R/W registers in Auto Load mode.
A8H
SCSI termination power fuse is blown, but termination power is still present at the 
SCSI connector.
ACH
SCSI termination power fuse is blown and termination power is not available at 
the SCSI connector.
B0H
Value Miscompare error of QLogic Fast SCSI chips R/W registers.
B4H
QLogic Fast SCSI chip did not generate a reset interrupt.
B8H
QLogic Fast SCSI chip registers not zeroed after reset.
BCH
SCSI bus hung, waiting for reset from QLogic Fast SCSI chip. Could be cabling.
D0H
Video RAM buffer error.
E5H
The onboard processor failed the accumulator test.
E8H
The onboard processor failed the store instruction test.
E9H
The onboard processor failed the shift instruction test.
ECH
The onboard processor failed the compare instruction test.
EDH
The onboard processor failed the jump instruction test.
Table 120: Self-test Status Port Error Codes