Ciprico Rimfire 3880 Manuel D’Utilisation

Page de 230
User’s Guide
21020285 D
Chapter 5   Initiator Mode Pass-through Commands
 
Initiator Pass-through Parameter Block Format
 Page 5 - 3
Initiator Pass-
through 
Parameter 
Block Format
In Chapter 4, a Base Parameter Block was introduced and explained in a general 
context. Parameter Blocks are the same size, with the same general fields, 
whether you are issuing a Pass-through command or an adapter Board-control 
command. The information specific to Initiator Pass-through commands will 
be covered in this section.
Command
Format
Use this format when issuing a Parameter Block containing an Initiator Pass-
through command:
Description of
the Fields
The Initiator Pass-through commands Parameter Block fields can be explained 
as follows:
Command Identifier
The Command Identifier field is used to identify the Status Block associated 
with a Parameter Block. 
It must be a unique value.
Target ID
This value identifies the Target ID of the device that is to receive the command 
contained in the SCSI Command Descriptor Block.
Address Modifier
This value further defines the VMEbus Address specified for a data transfer.
Note
Valid Address Modifier 
values can be found by 
referring to a VME 
Specification, Revision 
D.
Addr Mod Address Modifier
 - These six bits inform the RF3880 adapter 
what Address Modifier it should use for data transfer.
Address 
Offset
Byte Memory Address
Offset + 0
Offset + 1
Offset + 2
Offset + 3
00H
Command Identifier
04H
Flags-2
Flags-1
Addr. Mod.
Target ID
08H
VME Memory Address
0CH
Transfer Count
10H
0 (OP Code)
1
2
3
SCSI 6, 10 or 
12 byte 
Command 
Descriptor 
Block
14H
4
5
6
7
18H
8
9
10
11
Table 25: Initiator Pass-through Parameter Block
BITS
7
6
5
4
3
2
1
0
0
0
Addr  Mod
Table 26: Bit-meanings of Address Modifier Field