(4), and unplug the tool from its electrical outlet before 
performing inspection, maintenance, or cleaning procedures.
Damaged equipment can fail, causing personal injury.  Do 
not use damaged equipment.  if abnormal noise or vibration 
occurs, have the problem corrected before further use.
cleaning, maintenance, and lubrication
beFore each use, inspect the general condition of the tool.  Check for dam-
aged Soldering Iron (15) tip, loose screws, cracked or broken parts, damaged 
electrical wiring, and any other condition that may affect its safe operation.
aFter use, clean external surfaces and Soldering Tip. 
Warning!  if the supply cord of this power tool is damaged, it must be 
replaced only by a qualified service technician.
replacing the soldering iron
If Soldering Tip cracks or becomes eroded it must be replaced.  The Soldering 
Tip cannot heat up properly when cracked or eroded. 
heating contact (17)
soldering iron (15)
tip retainer (16)
Turn Power Switch (4) to the “OFF” position and unplug the Soldering Station 
from the electrical outlet.  Allow adequate time for all surfaces to cool down.
Unscrew Tip retainer (16) that holds the Soldering Iron (15) onto the Heating 
Contact (17) and remove the Soldering Iron. It may be necessary to force the 
Soldering Iron (15) out of the Tip retainer (16).  To do this, place the Soldering 
Iron on the side of the work bench, hold the Tip retainer, and push on it towards 
the Soldering Tip, forcing it out.  Be sure to wear ANSI-approved safety goggles 
and heavy-duty work gloves while doing this.
Place new Solder Tip on Heating Contact, replace Retainer, and finger-tighten.  
replacing the Fuse
Turn the Power Switch (4) to the “OFF” position, unplug the Soldering Station 
from the outlet, and allow time for all surfaces of the unit to cool down completely.
Turn the Soldering Station over and use a screwdriver to remove the cover 
marked “FUSE” on the bottom.  
remove the old fuse and replace with a new 6.3A/250V fuse of the same type.  
replace cover and screw back into place.