TCP/IP Ethernet Communications for the Series 90™ PLC User's Manual
 
 
 May 2002 
GFK-1541B
6
 
However, if you configure a routing table for PLCs B and C, their data may be forwarded to other
gateways. If Gateway G1 has been configured as the default gateway, the routing table could have
an entry for Subnet 2.2 via Gateway G2 and Subnet 2.3 via Gateway G3.  If the data is not
destined for either remote Subnet 2.2 or Subnet 2.3, then the data would be routed to Gateway G1,
the default gateway.
To configure a PLC on Subnet 2.1 to be able to communicate with Network 1, Subnet 2.2, and
Subnet 2.3 you need to know the following information.
Address of Gateway (G1) 
172.17.64.3 (Default Gateway)
Subnet Mask for Subnet 2.1:
255.255.192.0
Address of Gateway (G2)
172.17.64.4
Subnet Mask for Subnet 2.2:
255.255.192.0
Subnet ID of Subnet 2.2*:
172.17.128.0
Address of Gateway (G3)
172.17.64.5
Subnet Mask for Subnet 2.3:
255.255.192.0
Subnet ID of Subnet 2.3*:
172.17.192.0
* The subnet ID is derived by ANDing the bits of the subnet mask and an IP address on the
destination subnet.
Module Configuration for the Ethernet Interface in PLC B
The IP address, subnet mask, and default gateway IP address are entered in the Ethernet
Interface’s module configuration.
IP Address:  172.17.64.1
Subnet Mask:  255.255.192.0
Default Gateway IP Address:  172.17.64.3
PLC Routing Table to Configure Multiple Gateways for PLC B and PLC C
The following routing table entries are entered into the PLC’s Routing tab of the Name Resolution
and Routing Tables
 Rack Operation via the Windows-based PLC programming software (if
supported).
#
Destination Subnet ID
Destination Subnet Mask
Next Hop IP Address
(Gateway IP Address)
Cost
1
172.17.128.0
255.255.192.0
172.17.64.4
1
2
172.17.192.0
255.255.192.0
172.17.64.5
1