TOOLS REQUIRED FOR INSTALLATION / PARTS
    5/32"
(included)
          A (1)
[CPA264 Coupler]
F (1)
5/32"
1/2"
    1/2"
nut driver
1/2"
      B (4)
5/16-18 x 1"
D (4)
5/16"
C (4)
5/16"
       E (1)
5/16-18 x 1/2"
INSTALLATION
IMPORTANT ! : The following procedure assumes that a
1-1/2" NPT or NPSM following ANSI/ASME B1.20.1
(Schedule 40, 0.154" minimum thickness steel or
aluminum-ASTM B221) threaded extension column (not
included) has been properly installed following
instructions provided with extension column.
NOTE:
The CPA264 adapts a 1-1/2" NPT or NPSM following
ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum
thickness steel or aluminum-ASTM B221) threaded
extension column (not included); to a UL Listed CPA
extension column (not included).
1.
Thread CPA264 (A) onto a 1-1/2" NPT or NPSM following
ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum
thickness steel or aluminum-ASTM B221) threaded
extension column (not included) until tight, with a minimum
of four threads engaged. (See Figure 1)
2.
Install and tighten one 5/16" x 1/2" set screw (E) through
CPA264 and against column. (See Figure 1)
Figure 1
NOTE:
Installation of hex head self-tapping screws will be
easier when screws are carefully aligned with holes in
extension column, and a drill and nut driver is used. If a
drill will NOT be used, a small amount of pressure will
be needed to get the self-tapping screws started.
3.
Install UL Listed CPA extension column (not included)
following instructions included with extension column and
using four 5/16" x 1" self-tapping screws (B) through four
5/16" split lock washers (C), and four flat washers (D). (See
Figure 1)
1
(E) x 1
CPA extension
column (not
included)
1-1/2" NPT or
NPSM extension
column (not
included)
2
(B) x 4
3
(C) x 4
(D) x 4