RS485 Information
Communication parameters as specified in ANSI TIA/EIA-485-A:
Table 2:     COMMAND STRINGS FOR SL-220
The serial control command string is set up as follows:
Table 3: SERIAL CONTROL COMMAND STRING
Product ID for the SL-220: 05
Address controlled by dip switch settings
Basic Commands available for the SL-220 in the factory-supplied configuration:
03:  Cancel Move = 3E0500037D0D
10:  Extend to End of Travel = 3E0500107B0D
12:  Retract to End of Travel = 3E0500127D0D
Message Data = The data is required for the available commands:
03:  None
10: None
12:  None
Check Code is calculated.
Baud
Rate
Data
Length
Parity
Stop
Bit
Flow
Control
9600
8 Bits
None
1
None
Start of
Message
(HEX)
Product ID
(HEX)
Address
(HEX)
Command
(HEX)
Message Data
(HEX)
Check Code
(HEX)
End of
Message
(HEX)
3E
XX
XX
XX
XX
XX
0D