17)  Reverse steps 4) to 2).
18)  Attach clear label "This unit has been 
converted to LPG" near or on top of the 
serial # decal.
19)  Replace yellow "Natural Gas" label with 
red "LPG" label.
14)  Using the Allen wrench as shown in 
Fig.4, rotate the screw clockwise until 
snug, do not overtighten.
Fig.4
WARNING!
Do not overtighten the screw. 
Recommended to
grip the wrench by the short side.
15
)  Verify that if the conversion is from NG 
to LPG, the screw must be reassembled 
with the red o-ring visible (Fig. 5).
16
) Reassemble the black protection cap 
(Fig. 6).
WARNING!
Also check that the pilot and main
burner injectors 
are appropriate for the gas type. 
LPG Configuration
Red o-ring visible
Fig.5
Fig. 6
Installation of the DC Sparker 
for the H35-1 Units Only:
1) 
Remove the control panel by unscrewing 
the 2 screws.
3) 
Plug up the Piezo hole with the plastic 
bushing.
4) 
Attach the DC sparker generator 
connector to the valve with a screw.
5) 
Remove the stove’s rear panel by unscrew-
ing the two screws.
6) 
Attach the ground wire to the grounding 
stud.
2) 
First, remove the Piezo Ignition Wire 
from the Piezo Ignitor. Then remove the 
Piezo Ignitor from the control panel.
Before
After
INSTALLATION