Avaya Bogen Call Stacker Manuel De Montage

Page de 19
 
3-2 
Operation
Operation
Controls and Indicators
Figure 3-1.   Rear Panel Detail
Table 3-1.  Rear Panel Description
ITEM DESCRIPTION
Power On LED Illuminates when power is supplied to the Call Stacker.
Pause Override Control 
Input
Enables/disables the Page Output channel. When a contact 
closure (a short) between the two terminals is detected, the 
Call Stacker terminates the outgoing announcement (if any), 
requeues it and disables the Page Output channel. When 
the contact closure is removed, the Page Output channel is 
re-enabled and the terminated announcement plays to the 
paging system in its entirety (see note below).
Input Station 
(record) Channels
PBX and KTS analog station interfaces (tip/ring pairs) to the 
Public Telephone Network, a PABX or a Key System.
Page Output Channel
Audio and control contact signals to the paging system as 
shown in figure 2-3. Between outgoing announcements the 
control contact opens for a minimum of 250 msec. to release 
the paging system controller.
Option Switch Se
Battery Switch
Enables/disables battery backup. Turn the switch ON to 
enable the battery backup.
Power Input 110/120 VAC, 60Hz, power input
NOTE: The Input Station channels continue to operate when a contact closure is detected. Recorded 
announcements are held in a queue and play out sequentially (first in, first out) when the contact 
closure is removed.