Call detail recording (CDR)
Issue 9.1 June 2006
415
 
To administer CDR parameters
1. Type change system-parameters cdr and press RETURN.
The CDR System Parameters screen appears.
2. In the Primary Output Format field, enter a format specific to the call accounting system, if 
necessary. 
In the example, unformatted is used. If you were sending data directly to a printer, you 
would use printer.
3. In the Primary Output Endpoint field, type CDR1
4. If you use a secondary output device, and that device is also connected through TCP/IP, 
complete the Secondary Output Format field. 
Also, type CDR2 in the Secondary Output Endpoint field.
5. Press ENTER to save your changes.
change system-parameters cdr
Page
1 of
1
                            CDR SYSTEM PARAMETERS
Node Number (Local PBX ID):
CDR Date Format: month/day
      Primary Output Format: unformatted 
Primary Output Endpoint: CDR1
    Secondary Output Format: unformatted Secondary Output Endpoint: CDR2
           Use ISDN Layouts? n 
EIA Device Bit Rate: 9600
       Use Enhanced Formats? n 
Condition Code ‘T’ for Redirected Calls? n
Modified Circuit ID Display? n
Remove # From Called Number? n
                  Record Outgoing Calls Only? y
 Intra-switch CDR? n
  Suppress CDR for Ineffective Call Attempts? y 
CDR Call Splitting? y
      Disconnect Information in Place of FRL? n 
Outg Attd Call Record? y
Interworking Feat-flag? n
 Force Entry of Acct Code for Calls Marked on Toll Analysis Form? n
                                    Calls to Hunt Group - Record: member-ext
Record Called Vector Directory Number Instead of Group or Member? n
Record Called Agent Login ID Instead of Group or Member? n
Inc Trk Call Splitting? n
Record Non-Call-Assoc TSC? n
Call Record Handling Option: warning
Record Call-Assoc TSC? n   Digits to Record for Outgoing Calls: dialed
Privacy - Digits to Hide: 0               CDR Account Code Length: 4