Avaya 38DHB0002UKDD Manuel D’Utilisation

Page de 144
Software Upgrading and Installation 
Introduction - Page 9 
Software Upgrading and Installation 
Introduction 
The installation Wizard installs the IPNC Manager application on the 
Administration PC. 
Notes:  1.  The Configuration Wizard is contained on the Administration Software 
CD (which can also be accessed by running Setup.exe). The CD will 
auto run unless this feature has been disabled on the PC. 
2.  The IPNC Manager application is common to both INDeX IPNC and 
Avaya IP Office systems. However, the IPNC Manager application 
must not be installed on a PC being used to administer an Avaya 
Alchemy system. 
 
Installing Software Upgrade 
The following details the steps necessary to upgrade an IPNC 2.2 to 3.2 
software. 
To do this, it is necessary to first load IPNC 2.2 (1076) software to update the 
IPNC loader firmware to version 1.7, which is required in order to load IPNC 3.2 
software. 
CAUTION:  Before upgrading to 3.2 software, you must make a hard copy of 
the existing 2.2 configuration. This is necessary because, once the 
3.2 software has been loaded, it is not possible to reload an existing 
2.2 configuration file. The existing 2.2 configuration can then be re-
typed into the 3.2 Manager application. 
Notes:  1.  In the following, all commands in bold type are case sensitive and 
should be entered as specified. 
 
2.  In the following, it is assumed that the CD is in Drive D. 
 
Upgrade Steps  
Explanation 
Step 1 
Connect a terminal to the IPNC’s DTE maintenance 
port (see page 6). 
Open HyperTerminal (or similar) to communicate 
with the IPNC. 
Type at to test the connection. 
The IPNC should return, ‘OK’ if the terminal is 
correctly configured. 
 
In order to access the DTE port the 
HyperTerminal must be configured to operate 
as follows:- 
 
38400, 8, N, 1 
Step 2 
Save the current IPNC 2.2 configurations files to a 
new folder. 
 
Make a hard copy of the existing 2.2 configurations. 
 
 
In case it is necessary to abort the upgrade 
and return to the 2.2 build, you will need the 
configuration files. 
 
This hard copy will be needed for 
re-typing into the new 3.2 Manger application. 
 
 
INDeX IPNC Cassette Administration Manual 
Software Upgrading and Installation - Page 9 
38DHB0002UKDD – Issue 7 (22/11/02) 
Introduction