Apex Digital 5708009-C Manuel D’Utilisation

Page de 160
5708009-C
4-67
Apex 1 to 5.5 kW Generator
9
max ext 
feedback
Specifies the external feedback value that 
corresponds to 10 V on the User2 port; 
requires data bytes arranged as follows:
Second/third byte = a 16-bit value in the range 
of 500 to 5000.
Fourth byte = the number of decimal places (0 
to 4) used to display the external feedback 
signal on the operator panel.
3 data bytes
16-bit value
8-bit value
11
select active 
target
Specifies which target is active; accepts a 
value of 1 to 4. (Readback command is 156.)
1 data byte
8-bit value
12
set target 
life
Sets the life (in kWh) of the active target. 
Requires three data bytes (24-bit value):
Second, third, and fourth bytes = target life in 
kWh.
Two decimals are implied—to get 1 kWh, 
send a value of 100.
(Readback command is 157.)
3 data bytes
24-bit value
14
control 
transfer
Sets the active control mode of the generator; 
possible choices are: 2 = host, 4 = User port 
(analog).
1 data byte
8-bit value
15
out-of-
setpoint 
timer
Specifies how long the generator can produce 
output that is not equal to the programmed 
setpoint level. Accepts a value of 0 to 599 s. (0 
disables the timer.) (Readback command is 
184.)
2 data bytes
16-bit value
16
allowable 
deviation
Specifies a percentage that the generator can 
be out of setpoint before it starts the out-of-
setpoint timer. Accepts a value of 1 to 99%. 
(Readback command is 185.)
1 data byte
8-bit value
128
supply type
Requests the generator type; returns 4 ASCII 
characters.
0
4 data bytes
4 ASCII 
characters
129
supply size
Requests the output capacity of the generator; 
returning packet contains 4 ASCII characters.
0
4 data bytes
4 ASCII 
characters
Table 4-11. Profibus Host Port Commands (Continued)
Command
Description
Number of 
Transmit 
Data Bytes
Number of 
Response 
Data Bytes