Apex Digital 5708009-C Manuel D’Utilisation

Page de 160
5708009-C
5-7
Apex 1 to 5.5 kW Generator
ODU CONNECTOR
The following section describes the ODU input connector. To determine if your Apex 
unit has this connector, use the configuration PIN from your Apex unit and the 
following Configuration Note.
Figure 5-5 shows the ODU input connector. The pin numbers are labeled in the 
illustration.
Before making any input line power connection, turn off circuit breakers 
supplying input power to the Apex generator.
Non-standard connectors for input and/or output power must be 
inaccessible to the user.
If your unit does not have a circuit breaker, install and operate it with a 
circuit breaker on the ac input to provide over-current protection. The 
circuit breaker must have a trip value as specified in the line current 
section of Table 3-2. on page 3-5.
This section of the manual provides information for the:
ODU input connector
PIN position13
, (A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17) option A
(When identifying the PIN position, remember that the A at the beginning of 
the PIN is not counted as a position. The PIN option is the number or letter 
you should look for in the specified position.)
For more information about the PIN and for a complete list of how PIN 
positions correspond to Apex product options, see
 Table 1-1. on page 1-4.