4-19
Apex 1 to 5.5 kW Generator
4
6
RF POWER 
ENABLE
Digital 
input
RF output is enabled when a 4 to 
30 V input (pin 9, RF ON BIAS, 
can be used as a voltage source) 
is present on this pin.
Note: The interlocks must be 
satisfied and the setpoint 
must be within the Output 
power range before unit 
will deliver power. See 
Table 3-3. on page 3-6 for 
the Output power range 
specification.
5
6
FORWARD/LOAD 
POWER SETPOINT
Analog 
input
This analog signal provides a 
linearly scaled control of the 
forward or load output power 
depending on the regulation 
mode (1 V per 1 kW output 
power).
Note: The interlocks must be 
satisfied and the setpoint 
must be within the Output 
power range before unit 
will deliver power. See 
Table 3-3. on page 3-6 for 
the Output power range 
specification.
6
SIGNAL COMMON
Chassis 
ground
This pin is Signal Common. Also 
connected to Apex generator 
chassis ground.
7
6
RF ON STATUS
Digital 
output
+ 5 Vdc on this pin represents 
RF ON.
8
6
EXTERNAL BIAS
Voltage 
reference
+15 Vdc provided to the User 
port through a 5.62 k
Ω resistor.
Table 4-2. User Port (15-pin) Connector Pins Exclusive for Configuration D  (Continued)
Signal 
Pin
Return 
Pin
 Name
Signal 
Type
Description