Antunes, AJ MS-150/155 Manuel D’Utilisation

Page de 32
MIRACLE STEAMER
19
P/N 1010699 Rev. M 12/06
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel.  The unit should be unplugged when servicing, 
except when electrical tests are required.  
Problem
Possible Cause
Corrective Action
Control Display is Blank (power On/
Off switch is On but indicator light is 
off).
The power cord is not correctly 
plugged in.
Plug the power cord into the appro-
priate outlet.
The power cord and/or electrical 
plug is damaged.
Inspect electrical wire, plug, and 
receptacle. 
The main electrical panel circuit 
breaker is off or has been tripped.
Reset circuit breaker.  Contact your 
maintenance person or Authorized 
Service Agency if it trips again.
Switch is inoperable.
Contact your maintenance person or 
Authorized Service Agency for ser-
vice.
Control Display is blank (power On/
Off switch is on and indicator light is 
on).
Control Board is inoperable
Contact your maintenance person or 
Authorized Service Agency for ser-
vice.
Transformer is inoperable.
Loose, burnt, or broken wires in cir-
cuit.
Unit does not heat up (Control 
Display is on)
Hi-Limit Thermostat is tripped or 
inoperable.
Reset the Hi-Limit Thermostat 
according to the Operations sec-
tion of this manual.  If the Hi-Limit 
Thermostat requires continuous 
resetting, contact your Authorized 
Service Agency for service.
Solid State Relay is inoperable.
Thermocouple is inoperable.
Control Board is inoperable.
Steam Generator is inoperable.
Loose, burnt, or broken wires in cir-
cuit.
The unit’s main electrical panel cir-
cuit breaker trips.
Damaged receptacle, plug, or cord; 
a loose connection or an internal 
component failure.
Turn the unit off, allow it to cool to 
room temperature, and then restart 
the unit.  Contact your maintenance 
person or Authorized Service Agency 
if the condition repeats.
Water leaking inside electrical hous-
ing. 
Pinhole leak in rubber hoses (MS-
150/155/355).
Replace hoses.
Loose or damaged water line tubes 
and/or fittings inside electrical hous-
ing.
Tighten or replace tubes and/or fit-
tings.
ERR” appears in the Control 
Display.
Programming and/or SHO and 
H2O values were adjusted/changed 
improperly.
Reset the Control Board as 
described in the Programing section 
of this manual. See Fault Codes.