ALTINEX AP445-401 Manuel D’Utilisation

Page de 17
SPECIAL APPLICATION
400-0422-001
10
7.  [STAT]
This command displays the status of the 
AP445-401.
Command Format: [STAT] or [STATCi]
Ci = Unit ID (i = # from 0 to 99)
Example 1:
Send the command [STATC1] and receive 
feedback showing the status of unit ID 1.
Example 2:
Send the command [STAT] and receive 
feedback  showing the status of the unit 
connected to the RS-232 port regardless of its 
unit ID.
8.  [STATS]
This command displays the status of the 
AP445-401 and saves the settings in memory.
Command Format: [STATS] or [STATCiS]
Example:
Send the command [STATS] and receive 
feedback as in the previous example, but in this 
case the settings will be saved and recalled 
when the same input is selected using the [INR] 
command.
9.  [CLR]
Reset all parameters to factory defaults.
Command Format: [CLRCi]
Ci = Unit ID (i = # from 0 to 99)
Example:
Send the command [CLR] to reset the unit to 
the factory defaults. After reset, the status will 
similar to the following depending on the input 
selected:
Input: S-Video
Default
Output Resolution: 640x480
Last Saved
Brightness: 24
Last Saved
Contrast: 40
Last Saved
Color: 24
Last Saved
Sharpness: 10
Last Saved
Hue: 24
Last Saved
Audio Volume: 32
Default
VCR Mode
Default
NR ON
Default
Aspect Ration 4:3
Default
Freeze  OFF
Default
Front Panel Unlocked
Last Saved
10.  [IN]
This command selects the input port on the unit
to be used as the source.
Command Format: [INyCi]
y
= Input (y = # from 0 to 3)
0 =
S-Video
1 =
Composite Video
2 =
PC Bypass
3 =
YPbPr Video
Ci = Unit ID (i = # from 0 to 99)
Example:
Send the command [IN0] to select the S- Video 
input.
11.  [INR]
This command selects the input port on the unit
to be used as the source and recalls the saved 
settings.
Command Format: [INyRCi]
y
= Resolution (y = # from 0 to 3)
0 =
S-Video
1 =
Composite Video
2 =
PC Bypass
3 =
YPbPr Video
R = Recall image property settings