AeroComm CL4424 Manuel D’Utilisation

Page de 20
CL4424 User’s Manual
 
6/21/2005  
13
 
Figure 7- DCE to DCE Interface 
 
 
 
 
 
 
 
 
 
 
Note: The Straight Through Cable provided with the CL4424 has female connectors on both 
ends and the Crossover cable has a male connector at one end and a female connector at the 
other end.  Please use a male-to-male adapter or female-to-female adapter wherever required.  
Using a null modem adapter with a Crossover cable is equivalent to using a Straight Through 
cable. 
2.2 
RS-485 (2-wire Half Duplex) 
The RS-485 interface uses a Differential Data Transmission that can help nullify the effects of 
ground shifts and induced noise signals that can appear as common mode voltages on a 
network.  
The CL4424 implements a RS-485 (2-wire Half Duplex) multi-drop interface.  Typically, a RS-485 
bus will consist of a master and several slaves.  The nodes will have unique addresses and can 
send addressed packets to specific nodes.  Because the bus is half duplex, no two nodes should 
try to talk at the same time.  The CL4424 does not have a RS-485 address, therefore, it will 
transmit all RS-485 traffic over the RF.  Conversely, as soon as a CL4424 receives a packet over 
the RF, it will transmit the packet over the RS-485 bus. 
Note: When using RS-485 (2-wire Half Duplex), a RS-485 to RS-232 converter is required to 
configure the unit.  AeroComm recommends a B&B Electronics 4WSD9R converter to translate 
RS-485 to RS-232. 
 CTS 
     DCE 
     DCE 
    Crossover Cable 
CTS
 RTS 
RTS
 RXD
TXD
 TXD 
RXD
GND 
GND
 DCD
DTR
 DSR 
DSR
DCD
 DTR 
OEM Host 
CL4424 Modem 
NC
NC
 RI 
NC
RI
NC